Home / Catalog / Portable Ferrous Debris Monitor
PORTABLE

Portable Ferrous Debris Monitor

Ref. JPL-5

PQ in a field and lab format.

0–5500PQ (ppm)
1 ppmresolution
< 5 sresult
> 5 hbattery
Portable Ferrous Debris Monitor
Overview

Ferromagnetic wear quantified in 5 seconds

Same ferromagnetic particle quantification principle (PQ), in a portable format for quick analysis in the field or lab, with no sample pretreatment.

What it measures

What it measures

Ferromagnetic concentration

0–5500 mg/L (ppm)

Direct result in real concentration, with ±3% accuracy.

Method

ASTM D8120

Electromagnetic induction, no pretreatment and no solvents.

Repeatability

1% RSD

One data point every 5 seconds, with high stability.

How it works

Measurement principle

Same electromagnetic induction principle (PQ), in a portable bench format for spot samples.
1
2 mL sampleThe standard bottle receives the oil or grease sample.
2
Free fall into the sensorThe bottle drops vertically into the measuring coil.
3
Electromagnetic inductionFerromagnetic content changes the field and becomes a direct reading.
4
Result in ppmValue and trend appear on the 5-inch touch screen.
How to use

From the case to the result, no fuss

1
Power onStartup takes about 1 minute.
2
Check calibrationUse the standard sample that comes with the instrument; the screen guides the process.
3
Pipette 2 mLFill the standard bottle with the oil sample up to the mark.
4
Drop the bottle in the portIt free-falls vertically and the result comes out in under 5 seconds.
5
Save and follow upSet color-coded alerts, save the data and export via USB.
Technical data

Specifications

Code
JPL-5
Indicator
PQ index (ppm)
Range
0–5500 PQ
Method
ASTM D8120
Resolution
1 ppm
Accuracy
±3%
Sample / Time
2 mL · < 5 s
Screen
5" touch
Battery
3400 mAh · > 5 h
Storage
32 GB · USB export
Operating temperature
0 to 50 °C
Dimensions / Weight
255×215×130 mm · 2.85 kg
Power
AC 100–240 V 50/60 Hz

Full specifications in the official datasheet.

From the sensor to your system

Integration & Outputs

AC 100–240 V 50/60 Hz
Common questions

FAQ

Does it need solvents or pretreatment?
No. The 2 mL sample goes straight into the standard bottle, with no chemical preparation.
How long away from a power outlet?
More than 5 hours of operation on a full charge, with real-time battery indication.
Can I set alarms?
Yes. Two-level alert thresholds, with green, yellow and red lights on screen.
Portable Ferrous Debris MonitorAC 100–240 V 50/60 Hz · Ref. JPL-5
WhatsAppRequest a quote