ONLINE 24/7
Adsorption Wear Sensor
Ref. JWMA-W
Self-cleaning probe for ferromagnetic particles.
0–100%saturation (MDS)
9 mmadsorption distance
IP65protection
24/7continuous monitoring




Overview
The wear probe that cleans itself
Continuously adsorbs and detects particles; upon saturation (100%) it releases the material and automatically restarts the cycle (self-cleaning). Reports saturation (MDS) and self-cleaning interval (TLAG).
What it measures
What it reports
Particle saturation (MDS)
0–100% (1% resolution)
How much of the probe's capacity is already taken by ferromagnetic particles.
Self-cleaning interval (TLAG)
300–3600 s adjustable
The counting period between cycles, tuned to your system.
Adsorption distance
up to 9 mm
Probe capture reach in oils up to 100 mm²/s viscosity.
How it works
Measurement principle
Adsorption probe that continuously captures and detects ferromagnetic particles and, upon saturation (100%), releases the material and restarts the cycle (self-cleaning).
1
Continuous adsorptionThe probe captures the ferromagnetic particles present in the oil.
2
RecordingSaturation (MDS) grows as particles accumulate, telling fine from coarse at micrometric level.
3
Self-cleaningAt 100%, the probe releases the material and restarts the cycle on its own.
4
Digital outputMDS and TLAG published over RS485 MODBUS RTU.
Technical data
Specifications
Code
JWMA-W
Saturation
MDS (%)
Self-cleaning
TLAG interval
Installation
G1 thread · T6 aluminium probe
Output
RS485 MODBUS RTU
Power supply
DC 20–28 V
Adsorption distance
9 mm (≤100 mm²/s) · 8 mm (≤300) · 7 mm (≤500)
Dimensions / Weight
Ø46.8×104 mm · 200 g
Probe pressure / flow
max 10 bar · 0.1–2 m/s
Protection
IP65
Compliance
EN61326-1 · EN61326-2-3
Full specifications in the official datasheet.
From the sensor to your system
Integration & Outputs
◉Adsorption Wear Sensorinstalled at the measurement point
⇄RS485 MODBUS RTUopen industrial protocol
🖥PLC / SCADAyour alarms and history, in your standard
RS485 MODBUS RTU
Common questions
FAQ
What do MDS and TLAG mean?
MDS is the probe's particle saturation, from 0 to 100% with 1% resolution. TLAG is the self-cleaning interval, the counting period between cycles, adjustable from 300 to 3600 seconds.
Do I need to clean the probe manually?
No. Upon saturation, the probe releases the particles and restarts the cycle automatically.
How is it installed?
G1 thread, T6 aluminium probe, IP65 protection and DC 20–28 V supply.
Which oils and industries is it suited for?
Hydraulic, turbine, diesel, insulating and transformer oil. Applied in steel, petrochemical, power, wind, large equipment and OEM integration.